Error 5, No Slack on Cybex/Tectrix Climbmax 1000, 400S and 500S Steppers

Probable Cause

An error 5 on the Tectrix Climbmax model 1000 as well as Cybex stepper models 400S and 500S indicates the following:
a) Test switch is in test mode.
b) Possible cut in display cable.

Corrective Action

a) Adjust test switch.
b) Inspect display cable; replace cable if necessary.

Related Items