ErrE Error on Cybex/Trotter Pro, Sport and Elite Treadmills

Probable Cause

An ErrE error on the Cybex/Trotter Pro, Sport and Elite treadmills including models 450t, 500t, 515t, 520t and 530t indicates that the 0% is always on or the switch is disconnected or wired backwards. This means that timed elevation has gone up 2% and the index is still sensed.

The causes for an ErrE error:
a) Elevation calibration
b) Wiring

Corrective Action

a) Check the calibration of the elevation motor; Re-calibrate elevation motor if necessary.
b) Check wiring for 0 switch; Re-connect if necessary or re-wire if necessary.